Precise Vacuum UV Exposure
Unit for Screen Printing with Digital Display 15.7''×19.6'' 110V ASC6050ZK
Precise Vacuum UV Exposure Unit is equipped with special UV lamps and
auxiliary vacuum suction device. After putting the screens and well
printed transparency film on the glass, close its cover and let it work
after set the needed vacuum and exposure time, then it will make the
screens and transparency film close on the glass tightly by evacuating
the air of the vacuum charmer emerging from the rubber blanket. When the
set time is up, it will deflate automatically, and then the exposure is
finished. Please cut off the power supply. Working principle Screen printing screens are
coated with a light sensitive emulsion using a scoop coater. When the
emulsion is dry, place your image with a positive print on the screen.
Once you burn the screen, the emulsion that did not get any UV will wash
out of the screen exposing the tiny pin holes. The surrounding areas
that were exposed to UV will be cured. Hence the ink will pass through
screen onto your substrate. Essential Parameters · Input
Voltage: 110V · Exposure area: 15.7”*19.6” (40*50cm) · Vacuum Degree: -0.08Mpa · Illumination Uniformity: 85% · Lamp Power: 240W · Vacuum Pump Power: 60W · Vacuum Time Setting Range: 0-999s · Exposure Time Setting Range: 0-999s · Machine Size: 27.5”*27.5”*7” (70*70*18cm) · Package size: 31.3”*29.9”*9.5” (79.5*76*24cm) · Net weight: 47.4Lb / 21.5kg · Gross weight: 67Lb /30.4kg Special
Tips The vacuum pumping area (sizes
of the rubber blanket) is 19.6”*15.7” (50*40cm), (If your screen is
oversized, please buy cautiously!) Operation
Instructions 1. Connect the power supply;
Turn on the switch of “POWER”; 2. Set the vacuum pumping time
1) Press “VACUUM”, the left indicator light (yellow) is lit up; 2) Press “ + ” or “ – ” in the “TIME CONTROL” area to set the vacuum
pumping time according to your needs. (For first-time users, please put an empty screen in the middle of the
rubber inner cavity, just set 40 seconds for test; if the pointer of the
vacuum gauge could reach or pass the middle of the green area, that’s
ok. If not, please extend the time and test again until having reached
the requirement. 3 . Set the exposure
time 1) Press “EXPOSURE”, the left indicator light (red) is lit up; 2) Press “ + ” or “ – ” in the “TIME CONTROL” area to set the exposure
time according to your needs. (Exposure time varies according to the coated photosensitive emulsion.
Please just set 300 seconds for test and then reset a suitable time
according to the exposure effect.) 4 . Once finished the above settings, you
could start exposure just as follows 1) Put the screens coated with photosensitive emulsion and the printed
transparency film on the glass. 2) Put the air suction pipe in to the screen; 3) Close the cover and click the “START” button, then it will vacuum
pump and expose automatically according to the settings; 4) When the set time is up, it will deflate automatically; Open the
cover and exposure is finished. Please just cut off the power supply. 5. Functions of other keys 1) “RESET” for canceling the previous settings: if you want to reset the
vacuum / exposure time, just press “VACUUM” / “EXPOSURE” and the left
indicator light is lit up; Then press “RESET” and the original settings
will turn to “ 0 ”; Next, you could set according to your needs. 2) “BACK” for stop working: if you want to stop vacuum pumping or
exposure, just press the “BACK” button, that’s ok. Other details
Breakdown Maintenance 1. If the digit was not
displayed once turned on the switch a. Please check whether the power supply is good or not b. Please check whether the bottom fuse wire is loose,
burned-out or not 2. If the vacuum pump didn’t work after putting the screen on
the glass, closing the cover and pressing the “STRAT” button: Please check whether the leading wire of the vacuum pump is well
connected or not 3. If it didn’t reach the requirement even the vacuum pump works
well a. please checks whether the air suction pipe is well fastened
or not b. Please check whether the rubber blanket and its edgings were
good and seal or not. If there were some splits on the rubber blankets or edgings, or
some cracks of the edging adhesives, please fix them up with the
sealing adhesive. 4. If the lamps were not lit up a. Please check whether your voltage was too low or not b. Please check whether the lamp ends were blackened or not
caused by lamp ageing c. Please check whether your set exposure time was 0 second d.Please check whether the ballast was broken or not. Notice 1) Please cut off the
power supply when you need to change the lamp or the ballast 2) Avoid contact with hard objects to prevent glass surface
scratching 3) Consistent cleaning is needed according to your using
frequency and operational environment, especially for the glass,
vacuum rubber blanket and edgings
Item Number: Vacuum
Exposure Unit 110V--219106 You can make order with
no worry. Any concerns just feel free to let us know, we'll reply in 24
hours in normal condition. Handling Time: Shipping is usually made in 1-3 business days
after payments cleared. Orders are processed from Monday-Friday;
Not on the weekends & public holidays. Warranty: 6 months' warranty for the machines, not for the
consumables. We stand behind our products all the item, so even if your
warranty period has expired, you can still seek for service or
technical support from us with low cost. On Jul 21, 2023 at 02:03:09 PDT, seller added the following information:
Returns Accepted for this item if it's within 30 Days