VXS2121 Features : The product is mainly composed of a sensor, an adaptor, a USB connection cable and workstation software. Working together with an X-ray equipment, the Product is intended to make X-ray radiography in dental clinics or veterinary clinics , Sensor size Suitable for child ( adult single tooth ) and pets. Hardware Requirements : Central Processor: Intel Core i3 or higher Internal Memory: 4GB or higher Hard Disk: 80GB or higher Display: 1280X1024 USB interface: two Keyboard: One Mouse: One Software Requirement Operating Software : Windows 7 SP1,8,10 32/64bit Runtime: .Net Framework 4.6 or higher, VC++ 2015 Specification : Product Name: Image RVG x-ray Sensor Product Model : XVS2121 Operating Voltage:5VDC Input power : 500mW Spatial Resolution : ≥7Lp/mm Low contrast resolution : Able to display holes with 1mm, 1.5mm, 2mm and 2.5mm diameter on the 0.5mm-thick aluminium foil Image uniformity ≤2% Effective image area : 20.16*20.16mm Sensor Size : 26.5mm × 32mm × 11.7mm Adaptor Size : 60mm × 40mm × 29.2mm Total Cable Length: 3 m (sensor cable + control box cable to PC) Warranty:1 Year Accessory : Digital sensor: 1 Set USB cable :1 PC U Disk: 1PC Disposable protective sheath: 1 Box ( 500 ) Silicon loop: 1 PC Sensor holder: 1 PC Aluminum plate:1 PC (40*40*6mm) RAY-200 Features: 1.This portable dental X-ray unit is high frequency machine. 2.The body is small, light weight and nearly no radiation. 3.It has excellent image quality, portable storage, save more space. 4.It uses high frequency and DC international power supply. 5.All of the components installed in the central PC board concentrated. Shock,set-up, electron tubes, all of them are insulation vacuum, sealed stereotype protection. 6.There are also manual buttons installed on the surface of shell, as well as batteries and charges7.This unit mainly suitable for oral pre-treatment for learning internal organizational structure, root depth and so on, is indispensable in daily life clinic equipment, especially for dental implant surgery. 8.It also can connect with sensor, is great convenience. 9.The battery is durable, it can take about 5 hundred images after fully charged. 10.It can be connected with intra-oral digital X-ray imaging system. Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use
; After each photo taking, you need to wait for the normal value to return before taking a normal photo
。 Technical Parameter: Tube voltage
: 60KV Tube current
: 2mA Exposure time
: 0.1~2.0s Frequency
: 30KHz Rate power
: 120VA Distance from skin to cone
: 118mm Tube focus
: 0.4mm×0.4mm Battery
: DC14.8V 2200mAh Charger input voltage
: AC100V-240V±10% Output voltage: DC16.8V Ambient temperature: 5℃~40℃ Relative temperature: <75%RH Packing List: Main body 1pc Charger   1pc User manual 1pc BLX-5 Feature:

  • 1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
    2.) Toshiba 0.3mm x 0.3mm micro-focus tube
    3.) No protective operation room is needed when installing the complete machine.
    4.) Flexible adjustment of position and angle of handpiece
    5.) Compact in volume, light in weight, convenient for carrying
    6.) Time is adjustable, high contrast of picture, imaging in focus
    7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine
    8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
    9.) Non-film inspection and storage can be realized when corresponding to a sensor.
  • Specifications:

  • Voltage: 110v±10% and 220V±10%
    Power: 24V 8000MA
    Charger: 220V/110V, 50Hz
    Tube current: 0.1mA
    Rating: 60W
    Frequency: 30 KHz
    Exposure time: 1-9 seconds optional
    Leak radiation: < 20μgy/h(12lb)
    Focus Skin Distance: >20cm
    Tube voltage: 60KV
    Relative Humidity(RH) < 80%
    Storage conditions: 5-40 degrees Celsius, relative Humidity
    Net weight: 5.5 kg
    Dimension: 47 x 42 x 19 cm
  • Operation of the Main Unit:

  • 1. Upon receiving, open the box and check the product for possible damage during shipping.
    2. Make sure the fittings on the encasement list are packaged within the box
  • LK-C27
  • Feature:

  • 1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
    2.) Toshiba 0.3mm x 0.3mm micro-focus tube
    3.) No protective operation room is needed when installing the complete machine
    4.) Flexible adjustment of position and angle of handpiece
    5.) Compact in volume, light in weight, convenient for carrying
    6.) Time is adjustable, high contrast of picture, imaging in focus
    7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine
    8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
    9.) Non-film inspection and storage can be realized when corresponding to a sensor
  • Specifications:

  • Voltage: 110v±10% and 220V±10%
    Power: 24V 8000MA
    Charger: 220V/110V, 50Hz
    Tube current: 0.1mA
    Rating: 60W
    Frequency: 30 KHz
    Exposure time: 1-9 seconds optional
    Leak radiation: < 20μgy/h(12lb)
    Focus Skin Distance: >20cm
    Tube voltage: 60KV
    Relative Humidity(RH) < 80%
    Storage conditions: 5-40 degrees Celsius, relative Humidity
    Net weight: 5.5 kg
    Dimension: 47 x 42 x 19 cm
  • Operation of the Main Unit:

  • 1. Upon receiving, open the box and check the product for possible damage during shipping.
    2. Make sure the fittings on the encasement list are packaged within the box
  • BLX-5(8Plus)
  • Product introduction:

  • This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz,and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
  • TECHNICAL SPECIFICATIONS:

  • Tube Voltage
    60kV
    Tube Current
    1mA
    Time Exposure
    1~~9s
    High pressure generator
    30kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.3mm(TOSHIBA)
    Charger Input Voltage
    AC110V~220V
    Supply Frequency
    50Hz±1%
    Radiation Leakage
    <20ugy/h
    Battery
    24V DC 8000MA
    Weight
    4.3KG
    Dimensions
    37 cm×31 cm×28cm (L×W×H) Reference of the Angles :

  • Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
  • Reference of the time of exposure:

  • Tooth
    Adult
    Child
    Central & Lateral
    0.8-1.2
    0.8-1.0
    Cuspid & 1st Bicuspid
    1.2-1.4
    1.0- 1.2
    Upper 5,6
    1.6-1.8
    1.4-1.6
    Upper 7,8
    3.0-3.5
    2.8-3.3.
    Lower 5,6
    1.8-2.0.
    1.6-1.8
    Lower 7,8
    2.0-2.5
    1.8-2.3 Packing List:

  • Main machine 1pc

  • Power line 1pc

  • User manual 1pc
  • Operation of the Main Unit :

  • Upon receiving,open the box and check the product for possible damage during shipping.

  • Make sure the fittings on the encasement list are packaged within the box.

  • Install the blue ray tube to the foreside of the ball head,then tighten it.

  • Turn on the Power;the pilot lamp will be light up.During this time,the digital tube will show the fore setting time. Now the equipment is in standby mode.

  • Setting the time (Skip to next step if unneeded) Use the "SET","+",and" -" buttons to reset the time as follows: press SET,the pilot lamp above is illuminated, the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.

  • Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)

  • Keep the ball head plumb to the tooth projection position; Have the ball head,tooth, and tooth film steadily mutually plumb.

  • After positioning,use the ON/OFF on the main Unit, to take pictures. (Notice: gently press 0.5 sec to turn it on)

  • After exposure to the tube,press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray,so the dental films can be used again).

  • Repeat step 6 to reset the picturing time.To repeat the picturing process,please repeat steps 7 to 9.

  • Turn the power off when the work is finished,press POWER, making sure the pilot lamp is off.Don't keep the machine long in standby mode.
  • Points for Attention:

  • Make sure the angle of film,tooth,and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.

  • Remember to turn the power 0ff when work is done.

  • Charge the battery if the machine cannot work and the red lamp lignt.

  • After turning the power on,wait one minute before taking pictures,this allows the ray to provide a steady output.

  • The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of filming.

  • When taking pictures,the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.

  • Use high quality tooth film and developing liquid to make clear pictures.

  • Handle the ball head gently while in use,so as not to damage the delicate component.

  • We usually set the time between 3-8 seconds when taking pictures,but the actual time of ray output is 0.2-0.5 seconds.

  • If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.

  • Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.

  • Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.

  • Other requests accordance with the scope of the technical parameters.

  • Please read the manual carefully before using
  • SHIPS FREE *FROM* THE USA *TO* THE USA!!!
    No months-long wait from overseas! ❖ FDA Statement The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. Seller name:Dentistlove City,State:GuangDong,China Telephone number:075523387589 Re: K192233 Trade/Device Name: LED Curing Light Regulation Number: 21 CFR 872.6070 Regulation Name: Ultraviolet Activator for Polymerization Regulatory Class: Class II Product Code: EBZ Dated: December 7, 2019 Received: December 16, 2019

    Returns Accepted for this item if it's within 30 Days

    Dental Imaging System RVG X-Ray Sensor Size 1/Portable X-Ray Machine Equipment
    See more
    Price type
    IN STOCK OUT STOCK